Hall effect sensors: a method to measure passage time distributions of solid particles in solid-liquid flow

A method of measuring passage time distribution using Hall Effect Sensors is described in the following paper. Initially several practical problems were encountered, including the successful injection of tracers into the ohmic system and sensitivity calibration of the sensors. After these had been solved, Hall effect sensors were successfully used to measure particle passage times for 12 mm potato cubes, in 7% thermtex carrier fluid, in the heating column and holding sections of a 10kW ohmic heating plant. At a flowrate of 200 l/h, passage times in the column were found to be more spread out than in the holding tubes possibly indicating dead zones within the electrode geometry. / Une méthode pour mesurer la distribution, les temps de séjour basé sur les capteur à effet Hall est décrite dans ce papier. Originalement, de nombreux problèmes pratiques ont été rencontrés, incluant le problème de l`injection de traceur dans le système ohmique et la sensibilité des capteurs. Après la résolution de ces problèmes, les capteurs à effet Hall ont été utilisés avec succès pour mesurer les temps de séjour de particules pour des cubes de pommes de terre de 12 mm dans un fluide porteur à 7% dans une colonne de chauffage et dans les sections supports d'une usine de chauffage ohmique de 10kW. Lorsque le débit est de 200l par heure, les chercheurs ont trouvé des temps de séjour plus distribués dans la colonne que dans le tube support, ce qui indique probablement des zones mortes dans la géométrie de l'électrode.