Ultra-trace quantification of polar pesticides with a multi-residue HPLC-ESI-MS/MS method: comparison between a passive sampling technique and solid phase extraction.
With the implementation of the European Water Framework Directive, we need reliable, efficent and low cost methods for monitoring the freshwater quality. Pesticide pollutions are not only nefaste for the human health but also for aquatic organisms. We developed a multi residue method which allows detecting and quantifying 33 pesticides belonging to five different molecule families. This method was developed for two specific applications: analysis of solid-phase extraction (SPE) of pesticide traces in tap water, natural water and drinking water and analysis of Polar Organic Chemical Integrative Sampler (POCIS (Alvarez, Petty et al. 2000)) extracts. A particular attention was paid to the study of matrix effects, especially for the POCIS extracts. HPLC-ESI-MS/MS is now a reference and general technique for the water analysis because of its selectivity and its sensibility. However, this technique is commonly affected by some matrix effects (Taylor 2005; Niessen, Manini et al. 2006). There is several solutions to overcome these interferences: standard additions, internal standard calibrations, standard calibrations in the matrix of interest. ). We choose to work with internal standard calibrations with deuterium labelled pesticides since the two others approaches are time-consuming or inapplicable. This choice gave interesting results but the column choice brought the best improvement. Initially we worked with a 50 mm column and the first eluting molecules were highly impacted by matrix components. When we tested a 100 mm column, matrix effects were strongly decreased and these molecules showed lower signal suppression or enhancement.
One of the main interests of the POCIS is its high pre-concentration capacity which allows detecting polar chemicals at ultra-trace levels in waters. In comparison with SPE, a 14-day field exposure of POCIS typically corresponds to an extraction of about 1 to 3.5 L of natural water. Nevertheless, the POCIS pre-concentrate also others polar and interfering compounds from the matrix. It causes an important suppression effects for the most polar molecules and the use of appropriate internal standards is not sufficient to compensate these effects. We performed different dilutions of the POCIS extracts. A tenth dilution gave the best results with both very low limits of quantification (ppt level) and an acceptable minimization of the matrix effects. Combination of POCIS sampling, internal standard corrections and sample dilutions seems to be an efficient way to achieve ultra-trace quantifications.
Accès au document
| Lien externe vers le document: |