TREATMENT OF WASTEWATER FROM SLAUGHTERHOUSE BY DAF-UASB SYSTEM
A DAF-UASB reactor was tested as an alternative to a two stages Upflow Anaerobic Sludge Blanket for the treatment of slaughterhouse wastewater. A pilot plant was operated to ascertain Dissolved Air Flotation design parameters as pretreatment unit and evaluate the performance of UASB reactor with and without DAF. Experimental results are discussed.
Accès au document
Statut: | Consulter le site de l'éditeur pour accéder à cet article
|
Cote DDD: | 67/17018 |