PITTING CORROSION OF COPPER TUBES IN SOFT DRINKING WATERS : CORROSION MECHANNISM
The piping corrosion of copper tubes in drinking water systems is a sporadic but persistent problem along the east coast of Australia, New Zealand, and other locations where predominantly soft water is found. The author used novel microelectrode electrochemical techniques, supported by field observation and thermodynamics calculation, to propose a new mechanism of copper-pitting corrosion in soft waters. In this article, the authors also discuss how the theory may be applied to the development of a remedial water treatment strategy and used to calculate the optimum pH and alkalinity set points for a soft water.
Accès au document
| Statut: | Consulter le site de l'éditeur pour accéder à cet article
|
| Cote DDD: | 67/27603 |