Water supply system real time operational management Demo Case #1 Athens Greece Athens Demo Case aimed to deploy and demonstrate Fiwareenabled applications and services in the raw-water external conveyance system that serves the greater metropolitan area of Athens (Greece). The system, composed by more than 495km of aqueducts, is operated by Athens Water Supply and Sewerage Company (EYDAP S.A.), the largest water utility in Greece. The key target within Fiware4Water, was to upgrade the real-time operational management of the rawwater supply system by integrating data sources from different sensors and vendors, into a common information system, taking advantage of the data portability and integration functionalities of Fiware. NTUA and EYDAP designed and implemented a new Fiwareenabled platform, along with a series of analytics, for the demo part of the aqueduct, Giona to Dafnoula (131 km), integrating data from more than 60 sources, associated with both hydraulic (e.g., flow, water level) and quality (e.g., turbidity, temperature) system parameters. The web platform enables EYDAP to process, analyse and visualise data from the integrated sensors, allowing combined monitoring of flow and quality characteristics of raw water via a single web portal, on real-time basis. For this purpose, the Nessie system (Web Server and Data Analysis & Archiving Engine, developed by NTUA) was customised to the specific needs of Athens demo case. @EYDAP, External aqueduct of EYDAP Vasiliki Polychniatou EYDAP Demo case 1 leader Panagiotis Kossieris NTUA Christos Makropoulos KWR Back to content Back to the list scientific focus